Campaign
C7 campaign — extended-length peptides (20-24 aa)
2026-10-20
18 designs at 20-24 aa, 5 two-domain HITs. Viable, not superior to 15-18 aa.
basis: 2 experiments, 18 designs recorded, best ipSAE 0.834
01 / Goal
The one untried length class at the junction site.
2026-10-20 · 2 experiments · 18 designs · tools: BoltzGen, Boltz-2, IPSAE
- Answers: does a longer peptide beat the 15-18 aa band?
02 / Experiments
Each experiment: the method, the tools, the steps — and its proteins, folded. The climb first.
The best score each phase reached — the campaign's climb. ipSAE / pDockQ2 = best interface scores of the phase; activation = the strongest geometry reached (of 6 pharmacophore contacts, with insertion depth).
| phase | ipSAE | pDockQ2 | activation | designs |
|---|---|---|---|---|
| The 20-24 aa sampling + folds | 0.834 | 0.593 | 5/6 d25.0 | 18 |
01 · The 20-24 aa sampling + folds 2026-10-20
tools BoltzGenBoltz-2IPSAE
30 single-design runs at the junction, then the standard fold and screen.
- 01 · Sample 30 designs
- 02 · Fold against the full receptor
- 03 · Screen
Outcome. 5 two-domain HITs; the length question answered.
Proteins · 18 designs · 18 scored
| design | score | sites (h/m) | groove | TM | ECL3 | agon | ipsae_min | pDockQ2 | ipTM | sequence |
|---|---|---|---|---|---|---|---|---|---|---|
c7-run1 | 57.1 / 100 | — / — | 6/6 | 2/4 | 5/8 | 4/6 d13.5 | 0.819 | 0.281 | 0.949 | seqGRVIRVTAEVEGITVPVELTLPS |
c7-run11 | 59.9 / 100 | — / — | 6/6 | 2/4 | 7/8 | 4/6 d17.2 | 0.812 | 0.264 | 0.952 | seqTVSLPTTIKLGDREVKVNGIDPTL |
c7-run14 | 42.0 / 100 | — / — | 1/6 | 4/4 | 5/8 | 4/6 d22.5 | 0.732 | 0.117 | 0.926 | seqKRVIHVTDPITGKTLTFTLPG |
c7-run15 | 43.0 / 100 | — / — | 3/6 | 2/4 | 4/8 | 4/6 d18.2 | 0.721 | 0.149 | 0.938 | seqSRLELKVNPLTGKVSFDLSK |
c7-run18 | 67.1 / 100 | — / — | 1/6 | 3/4 | 5/8 | 5/6 d25.0 | 0.814 | 0.187 | 0.942 | seqTGAPMTTTVGGVTLKVYSPL |
c7-run2 | 29.0 / 100 | — / — | 0/6 | 0/4 | 0/8 | 0/6 d59.2 | 0.713 | 0.593 | 0.945 | seqCPPCLTVNPVTGKVTVDPSC |
c7-run21 | 46.6 / 100 | — / — | 2/6 | 1/4 | 4/8 | 4/6 d19.8 | 0.720 | 0.398 | 0.907 | seqSRLVPELVSVSLTGATYRLVRVG |
c7-run22 | 57.5 / 100 | — / — | 5/6 | 2/4 | 5/8 | 3/6 d15.9 | 0.819 | 0.306 | 0.959 | seqTVSVPVTVTIGGVPIKVTAYTPD |
c7-run23 | 61.6 / 100 | — / — | 1/6 | 4/4 | 4/8 | 5/6 d19.2 | 0.761 | 0.170 | 0.939 | seqTVAKVSVDPKTGKPVFTSVG |
c7-run24 | 50.0 / 100 | — / — | 2/6 | 1/4 | 5/8 | 3/6 d14.0 | 0.832 | 0.230 | 0.947 | seqTGATGKTVLPGTGLVLTFTDPL |
c7-run26 | 35.3 / 100 | — / — | 6/6 | 0/4 | 0/8 | 1/6 d8.7 | 0.725 | 0.226 | 0.910 | seqMPIFEVNPLTGKFTIKPGKD |
c7-run28 | 40.3 / 100 | — / — | 4/6 | 1/4 | 3/8 | 3/6 d14.0 | 0.410 | 0.097 | 0.787 | seqSGRVIKVPTPDGRTLELPIPG |
c7-run29 | 49.1 / 100 | — / — | 1/6 | 2/4 | 7/8 | 4/6 d19.6 | 0.752 | 0.243 | 0.939 | seqTVPVEMTVPGTGLVVTVEDL |
c7-run3 | 57.5 / 100 | — / — | 5/6 | 2/4 | 5/8 | 4/6 d17.7 | 0.790 | 0.406 | 0.943 | seqMRTVTVEAIDPVTGESRPVELTFG |
c7-run4 | 30.9 / 100 | — / — | 1/6 | 2/4 | 4/8 | 3/6 d19.6 | 0.750 | 0.395 | 0.955 | seqTVARVYRDPETGKAKFEAVG |
c7-run6 | 56.6 / 100 | — / — | 3/6 | 2/4 | 3/8 | 5/6 d20.2 | 0.589 | 0.145 | 0.864 | seqCGVKVTVTLTTPDGESFPVTLTLP |
c7-run8 | 38.7 / 100 | — / — | 4/6 | 2/4 | 2/8 | 2/6 d16.3 | 0.735 | 0.221 | 0.921 | seqCKPKLEVVKLSPFDPEVRVYLDK |
c7-run9 | 57.4 / 100 | — / — | 5/6 | 1/4 | 2/8 | 2/6 d17.4 | 0.834 | 0.367 | 0.962 | seqSGVTITTTDEFGRKLTMTIPG |
What the columns mean:
- groove — Contacts at the GLP-1 binding groove (of 6 residues). The address half of the site: filling it makes a binder, not necessarily an agonist. (higher is better)
- TM pocket — Contacts in the transmembrane pocket (of 4). The deeper, message-side region — the reach that matters for activation. (higher is better)
- ECL3 — Contacts on outer loop 3 (of 8). ECL3 moves when the receptor switches on; contact there is part of the activation pattern. (higher is better)
- activation geometry — The GLP-1 message-region pharmacophore: contacts of 6 plus insertion depth below the vestibule rim, from the calibrated activation gate. 6/6 at depth >= 16 A is the full agonist pattern. (higher is better)
- ipSAE min — The weaker of the two interface directions. The best single lab-binding predictor in the 2025 meta-analysis. (higher is better)
- pDockQ2 — Interface quality that counts only the interface residues. The second half of the acceptance bar (>= 0.23). (higher is better)
- ipTM — Predicted interface TM. Stays high even when the interface score collapses — never decide on ipTM alone. (higher is better)
02 · Outcome — partial 2026-10-20
Longer peptides cover more groove (two touch all six residues) but do not beat 15-18 aa on affinity (best 0.834 vs 0.934).
Outcome. Campaign verdict: partial.
03 / Results — this campaign's best designs
None of this campaign's designs are in the submission set; its best reads stand as the campaign record.
| design | score | ipSAE | pDockQ2 | ipTM |
|---|---|---|---|---|
c7-run9 | 57.4 / 100 | 0.8342 | 0.3671 | 0.962 |
c7-run24 | 50.0 / 100 | 0.8321 | 0.2297 | 0.947 |
c7-run22 | 57.5 / 100 | 0.8189 | 0.3058 | 0.959 |
c7-run1 | 57.1 / 100 | 0.8187 | 0.2806 | 0.949 |
c7-run18 | 67.1 / 100 | 0.8144 | 0.1868 | 0.942 |
c7-run11 | 59.9 / 100 | 0.8118 | 0.2642 | 0.952 |
c7-run3 | 57.5 / 100 | 0.7896 | 0.4065 | 0.943 |
c7-run23 | 61.6 / 100 | 0.7612 | 0.1696 | 0.939 |
c7-run29 | 49.1 / 100 | 0.7517 | 0.2432 | 0.939 |
c7-run4 | 30.9 / 100 | 0.7499 | 0.3948 | 0.955 |
c7-run8 | 38.7 / 100 | 0.7347 | 0.2213 | 0.921 |
c7-run14 | 42.0 / 100 | 0.7322 | 0.1175 | 0.926 |
What the columns mean:
- ipSAE min — The weaker of the two interface directions. The best single lab-binding predictor in the 2025 meta-analysis. (higher is better)
- pDockQ2 — Interface quality that counts only the interface residues. The second half of the acceptance bar (>= 0.23). (higher is better)
- ipTM — Predicted interface TM. Stays high even when the interface score collapses — never decide on ipTM alone. (higher is better)
- selection score (0-100) — The primary selection score, from select-top20.py: 100 x (2.0*A + 1.5*B + 1.0*E + 0.5*R) / 25. A = activation geometry (how many of the 6 agonist features the pose meets, and whether samples agree), B = binding (ipSAE, with a bonus for pDockQ2 >= 0.30), E = expression (pLDDT band + Kyte-Doolittle hydropathy), R = epitope reach. Each component is capped at 5, so the weighted total caps at 25. The six epitope-gate additions of 2026-11-04 carry the v4 composite instead (25 i_pDAE + 15 ipTM + 15 dfree + 15 E + 10 dWT + 20 peptide_read): same 0-100 scale, different formula. Row order is this score, descending. (higher is better)
04 / Binding
The designs of this experiment on Human GLP-1 receptor (UniProt P43220, residues 24-432; ECD and ECD-TMD junction)., in the structure explorer. The eye icon on the left toolbar opens the design list (one or many, with scores); Coloring Options switches pLDDT / hydrophobicity / interface — or back to the default design colours.
targetthe protein to bind
designed binderthe design
interfacethe residues that touch